The wafer style sensing element mounts directly into existing pipelines between two standard 150-lb. flat or raised-faced flanges
Each Clear Line detector is factory-calibrated to provide reliable, repeatable performance regardless of changes in process fluids and coatings, or variations in temperature, conductivity, and density.
The wafer style sensing element mounts directly into existing pipelines between two standard 150-lb. flat or raised-faced flanges
Each Clear Line detector is factory-calibrated to provide reliable, repeatable performance regardless of changes in process fluids and coatings, or variations in temperature, conductivity, and density.
Electronic Unit for mounting remotely from sensing element
Sensing Element with cooling extension, inactive, all metal wetted parts 316 SS standard
Electronic Unit for mounting remotely from sensing element
Sensing Element with cooling extension, inactive, all metal wetted parts 316 SS standard
The IntelliPoint electronics use a universal power supply module that can be powered from a 85 to 250 Vac or 21 to 100 Vdc supply without moving jumpers.
Automatic and manual test functions ensure proper system operation. An AutoVerify™ self-check circuit continuously monitors that the complete system is functioning properly.
The IntelliPoint electronics use a universal power supply module that can be powered from a 85 to 250 Vac or 21 to 100 Vdc supply without moving jumpers.
Automatic and manual test functions ensure proper system operation. An AutoVerify™ self-check circuit continuously monitors that the complete system is functioning properly.
Unique diagnostic output provides float position beyond set span, beyond active range, as well as loss of float
0.1% accuracy full scale over 4-20mA span
Unique diagnostic output provides float position beyond set span, beyond active range, as well as loss of float
0.1% accuracy full scale over 4-20mA span
Unique diagnostic output provides float position beyond active range, as well as loss of float(s).
0.01% of measured span - less than 1 mm absolute, over full measurement range.
Unique diagnostic output provides float position beyond active range, as well as loss of float(s).
0.01% of measured span - less than 1 mm absolute, over full measurement range.
Field Adjustable lengths from 1' to 15' (0.3 to 4.57 m) 12" to 180" (305mm to 4572 mm)
Alarm trip points with any contact of internal or external roof
Field Adjustable lengths from 1' to 15' (0.3 to 4.57 m) 12" to 180" (305mm to 4572 mm)
Alarm trip points with any contact of internal or external roof
Detects the absence or presence of liquids, slurries, and granulars
ThePoint electronics use a universal power supply module that can be powered from a 19 to 250 Vac or 18 to 200 Vdc supply without moving jumpers.
Detects the absence or presence of liquids, slurries, and granulars
ThePoint electronics use a universal power supply module that can be powered from a 19 to 250 Vac or 18 to 200 Vdc supply without moving jumpers.
Unlike many technologies, electronics can be remote mounted to a convenient or safe location.
In addition to lower initial investment, ThePoint continues to save with little or no maintenance compared with other technologies. Further, the sensor can be lengthened or shortened in the field, saving the need for additional purchases.
Unlike many technologies, electronics can be remote mounted to a convenient or safe location.
In addition to lower initial investment, ThePoint continues to save with little or no maintenance compared with other technologies. Further, the sensor can be lengthened or shortened in the field, saving the need for additional purchases.
Drexelbrooks Cote-Shield circuitry “Sees” through any coating condition and eliminates false plugged chute signals
DPDT relay dry contacts at 5A, 120VAC.
Drexelbrooks Cote-Shield circuitry “Sees” through any coating condition and eliminates false plugged chute signals
DPDT relay dry contacts at 5A, 120VAC.
The Two-Wire, DC-Powered, Electronics can be remotely mounted up to 100 feet from the sensing element, or integrally mounted with the sensing element. All transmitters and signal wires are intrinsically safe when used with an approved power supply.
No moving parts to deteriorate or break down.
No routine cleaning or recalibration necessary.
The Two-Wire, DC-Powered, Electronics can be remotely mounted up to 100 feet from the sensing element, or integrally mounted with the sensing element. All transmitters and signal wires are intrinsically safe when used with an approved power supply.
No moving parts to deteriorate or break down.
No routine cleaning or recalibration necessary.
The Universal V CM comes factory pre-calibrated to one of 11 pre-set ranges, for Light Oil (API Gravity > 25) and Heavy Oil (API Gravity < 25
The proven Cote-Shield is designed into the Universal V CM series and enables the instrument to ignore a pre-determined length of the sensing element. The ability to ignore a pre-determined length allows the sensing element to extend into the fluid beyond the nozzle mounting, and possible
The Universal V CM comes factory pre-calibrated to one of 11 pre-set ranges, for Light Oil (API Gravity > 25) and Heavy Oil (API Gravity < 25
The proven Cote-Shield is designed into the Universal V CM series and enables the instrument to ignore a pre-determined length of the sensing element. The ability to ignore a pre-determined length allows the sensing element to extend into the fluid beyond the nozzle mounting, and possible
The dielectric constant of crude oil can change with any changes in temperature. These changes may cause standard cut monitors to change without any variance in water content. The Universal V Water Cut Monitor measures product temperature internally and calculates a true water cut reading at any temperature within the process temperature range
The Universal V CM Model has been approved for ClassI, Div1 hazardous locations. FM and FMc, ATEX and IECEX approvals are available
The dielectric constant of crude oil can change with any changes in temperature. These changes may cause standard cut monitors to change without any variance in water content. The Universal V Water Cut Monitor measures product temperature internally and calculates a true water cut reading at any temperature within the process temperature range
The Universal V CM Model has been approved for ClassI, Div1 hazardous locations. FM and FMc, ATEX and IECEX approvals are available
2-wire, 4-20mA loop transmitter with the widely accepted digital HART protocol
Process temperature from cryogenic to (537°C)
2-wire, 4-20mA loop transmitter with the widely accepted digital HART protocol
Process temperature from cryogenic to (537°C)
Output signal
2-wire, 4-20mA, HART (isolated)
±0.15% or 0.2 inch (5 mm) of sensor range, whichever is greater
Output signal
2-wire, 4-20mA, HART (isolated)
±0.15% or 0.2 inch (5 mm) of sensor range, whichever is greater
One-piece unit is easily installed through a single 3/4-inch, probe dependent vessel opening. Calibration is quick and simple
Cote-Shield™ circuitry allows the Z-tron IV to ignore coatings or build up on the sensing element. There are no false signals from dust or tunneling.
One-piece unit is easily installed through a single 3/4-inch, probe dependent vessel opening. Calibration is quick and simple
Cote-Shield™ circuitry allows the Z-tron IV to ignore coatings or build up on the sensing element. There are no false signals from dust or tunneling.
Copyright © 2024 Pinnacle Instruments. All rights reserved.